    The HP 4200 vl Switch Series consists of modular chassis that provide a flexible, cost-effective LAN solution as an alternative to stackable switches. These switches offer a proven chassis form factor with high quality and reliability in 10/100, 10/100/1000, and 10-Gigabit scalable solutions that integrate easily into any network.

    Quality of Service (QoS)
    • Traffic prioritization (IEEE 802.1p): allows real-time traffic classification into eight priority levels mapped to eight queues

    Management
    • Uni-Directional Link Detection (UDLD): monitors cable between two switches and shuts down the ports on both ends if the cable is broken, turning the bidirectional link into a unidirectional one; this prevents network problems such as loops

    Connectivity
    • Auto-MDIX: automatically adjusts for straight-through or crossover cables on all 10/100 and 10/100/1000 ports

    Performance
    • Architecture: up to 76.8 Gbps crossbar switching fabric provides wire-speed intra- and inter-module switching with up to 48 million pps throughput built on HP custom-designed ASIC technology

    Resiliency and high availability
    • IEEE 802.3ad Link Aggregation Control Protocol (LACP) and HP port trunking: support up to 60 trunks, each with up to eight links (ports) per trunk

    Manageability
    • sFlow (RFC 3176): wire-speed traffic accounting and monitoring

    Layer 2 switching
    • VLAN support and tagging: supports IEEE 802.1Q (4,094 VLAN IDs) and 256 VLANs simultaneously

  • Technical Data
    Ports & interfaces
    I/O ports2 open module slots; 72 auto-sensing 10/100 ports(IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX), Media Type: Auto-MDIX, Duplex: half or full; Supports a maximum of 120 auto-sensing 10/100 ports or 48 Gigabit ports or 8 mini-GBICs or 2 10-GbE ports, or a combination
    Basic switching RJ-45 Ethernet ports quantity72
    Console portRS-232
    Performance
    Packet buffer memory36 MB
    StackableNo
    Processor frequency330 MHz
    Internal memory64 MB
    Flash memory24 MB
    Built-in processorYes
    Processor modelPowerPC MPC8245
    Weight & dimensions
    Weight (imperial)Fully loaded 23.81 lb.
    Weight10.8 kg
    Power
    Input voltage100-127 / 200-240 VAC
    Power supply slots open1
    Power consumption (typical)630 W
    Input current3.8 – 8.2 A
    Power source1 x J4839A
    Technical details
    StackableNo
    Processor frequency330 MHz
    Switch fabric speed33.6 Gbps
    Supported protocolsGeneral protocols HTML and telnet management IEEE 802.1AB Link Layer Discovery Protocol (LLDP); RFC 1757 RMON 4 groups: Stats, History, Alarms and Events; RFC 2819 Four groups of RMON: 1 (statistics), 2 (history), 3 (alarm) and 9 (events); RFC 3164 BSD syslog Protocol; RFC 3176 sFlow; ANSI/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED); SNMPv1/v2c/v3; XRMON Network management MIBs Device management IP multicast IEEE 802.1D MAC Bridges; IEEE 802.1p Priority; IEEE 802.1Q VLANs; IEEE 802.1s Multiple Spanning Trees; IEEE 802.1w Rapid Reconfiguration of Spanning Tree; IEEE 802.3ad Link Aggregation Control Protocol (LACP); IEEE 802.3x Flow Control; RFC 768 UDP; RFC 783 TFTP Protocol (revision 2); RFC 791 IP; RFC 792 ICMP; RFC 793 TCP; RFC 826 ARP; RFC 854 TELNET; RFC 1542 BOOTP Extensions; RFC 2030 Simple Network Time Protocol (SNTP) v4; RFC 3046 DHCP Relay Agent Information Option Security RFC 1213 MIB II; RFC 1493 Bridge MIB; RFC 2613 SMON MIB; RFC 2618 RADIUS Client MIB; RFC 2665 Ethernet-Like-MIB; RFC 2668 802.3 MAU MIB; RFC 2737 Entity MIB (Version 2) QoS/Cos RFC 2474 DiffServ Precedence, including 8 queues/port; RFC 2597 DiffServ Assured Forwarding (AF); RFC 2598 DiffServ Expedited Forwarding (EF) IEEE 802.1X Port Based Network Access Control; RFC 2138 RADIUS Authentication; Secure Sockets Layer (SSL); SSHv2 Secure Shell RFC 3376 IGMPv3
    Operating altitude (imperial)up to 15000 ft.
    Management product nameHP ProCurve Manager Plus; HP ProCurve Manager (included)
    Electromagnetic immunityEN 55024, CISPR 24; IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6; IEC 61000-4-8; IEC 61000-4-11; EN 61000-3-2, IEC 61000-3-2; EN 61000-3-3, IEC 61000-3-3
    Built-in processorYes
    Management features
    Switch typeManaged
    MIB supportRepeater MIB; Ethernet Interface MIB; IEEE 802.3 Ethernet MIB
    Data transmission
    Throughputup to 22.4 million pps
    Packet buffer memory36 MB
    Switching capacity38.4 Gbit/s
    Maximum data transfer rate0.1 Gbit/s
    Protocols
    Supported network protocolsRFC 783 TFTP; RFC 1542 BootP; RFC 768 UDP; RFC 792 ICMP; RFC 793 TCP; RFC 826 ARP; RFC 2030 SNTP; RFC 2030 Simple Network Time Protocol; IEEE 802.3x Flow Control; DHCP Relay; RFC 3046 DHCP Relay Agent Information Option 82; RFC 3376 IGMPv1/v2/v3; IEEE 802.1D Spanning Tree; IEEE 802.1w Rapid Convergence Spanning Tree; IEEE 802.1s Multiple Spanning Trees; IEEE 802.3ad Link Aggregation Control Protocol; IEEE 802.1AB Link Layer Discovery Protocol; ANSI/TIA-1057 LLDP Media Endpoint Discovery (MED); RFC 2474 DiffServ Precedence; RFC 2598 DiffServ Expedited Forwarding (EF); RFC 2597 DiffServ Assured Forwarding (AF); RFC 2138 RADIUS; SSHv2 Secure Shell; Secure Sockets Layer (SSL); IEEE 802.1X Network Login; IEEE 802.1Q VLAN tagging; IEEE 802.1Q GVRP; IEEE 802.1p Priority; SNMPv1/v2c/v3; RFC 1493 Bridge MIB; RFC 1213 MIB II; RFC 2737 Entity MIB; RFC 2665 Ethernet MIB; RFC 2668 802.3 MAU MIB; RFC 2819 Four groups of RMON: 1 (statistics), 2 (history), 3 (alarm) and 9 (events); RFC 3164 Syslog; XRMON; RFC 2613 SMON; RFC 2618 RADIUS Client MIB; RFC 791 IP; RFC 1757 RMON Groups 1,2,3,9; RFC 3176 sFlow
    Supported protocolsGeneral protocols HTML and telnet management IEEE 802.1AB Link Layer Discovery Protocol (LLDP); RFC 1757 RMON 4 groups: Stats, History, Alarms and Events; RFC 2819 Four groups of RMON: 1 (statistics), 2 (history), 3 (alarm) and 9 (events); RFC 3164 BSD syslog Protocol; RFC 3176 sFlow; ANSI/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED); SNMPv1/v2c/v3; XRMON Network management MIBs Device management IP multicast IEEE 802.1D MAC Bridges; IEEE 802.1p Priority; IEEE 802.1Q VLANs; IEEE 802.1s Multiple Spanning Trees; IEEE 802.1w Rapid Reconfiguration of Spanning Tree; IEEE 802.3ad Link Aggregation Control Protocol (LACP); IEEE 802.3x Flow Control; RFC 768 UDP; RFC 783 TFTP Protocol (revision 2); RFC 791 IP; RFC 792 ICMP; RFC 793 TCP; RFC 826 ARP; RFC 854 TELNET; RFC 1542 BOOTP Extensions; RFC 2030 Simple Network Time Protocol (SNTP) v4; RFC 3046 DHCP Relay Agent Information Option Security RFC 1213 MIB II; RFC 1493 Bridge MIB; RFC 2613 SMON MIB; RFC 2618 RADIUS Client MIB; RFC 2665 Ethernet-Like-MIB; RFC 2668 802.3 MAU MIB; RFC 2737 Entity MIB (Version 2) QoS/Cos RFC 2474 DiffServ Precedence, including 8 queues/port; RFC 2597 DiffServ Assured Forwarding (AF); RFC 2598 DiffServ Expedited Forwarding (EF) IEEE 802.1X Port Based Network Access Control; RFC 2138 RADIUS Authentication; Secure Sockets Layer (SSL); SSHv2 Secure Shell RFC 3376 IGMPv3
    Certificates
    SafetyCSA 22.2 No. 950; UL 60950; EN 60950
    Electromagnetic compatibilityFCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A; CISPR 22 Class A; EN 55024; IEC/EN 61000-3-2; IEC/EN 61000-3-3
    Electromagnetic emissionsFCC Class A; VCCI Class A; EN55022/CISPR-22 Class A; CISPR22 Class A; EN55024; IEC/EN61000-3-2; IEC/EN61000-3-3
    Memory
    Packet buffer memory36 MB
    Internal memory64 MB
    Flash memory24 MB
    Design
    SafetyCSA 22.2 No. 950; UL 60950; EN 60950
    StackableNo
    Electromagnetic compatibilityFCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A; CISPR 22 Class A; EN 55024; IEC/EN 61000-3-2; IEC/EN 61000-3-3
    Power over Ethernet (PoE)
    Power over Ethernet (PoE)No
    Operational conditions
    Storage temperature (T-T)-40 – 70 °C
    Operating temperature (T-T)32 – 104 °F
    Operating temperature (T-T)0 – 40 °C
    Packaging data
    Package weight7.19 kg
    Other features
    Management platformHP PCM+; HP PCM (included); command-line interface; Web browser; configuration menu; out-of-band management (DB-9 serial port console); IEEE 802.3 Ethernet MIB; Repeater MIB; Ethernet Interface MIB
    LatencyLatency: < 6 µs (FIFO)
    Data transfer rate10 Mbit/s
    Dimensions (WxDxH)388.6 x 442 x 133.4 mm
    Connectivity technologyWired
    Remote administrationcommand-line interface; Web browser; configuration menu; out-of-band management (DB-9 serial port console)
    Power requirements100-127 VAC/200-240 VAC; 50/60 Hz
    MountingMounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only.
    Memory and processorFabric: Motorola PowerPC MPC8245 @ 330 MHz, 24 MB flash, packet buffer size: 36 MB, 64 MB SDRAM
    Input voltage100-127 / 200-240 VAC
    Input frequency50 / 60 Hz
    Weight (imperial)Fully loaded 23.81 lb.
    Switch fabric speed33.6 Gbps
    Power supply slots open1
    Operating altitude (imperial)up to 15000 ft.
    Management product nameHP ProCurve Manager Plus; HP ProCurve Manager (included)
    I/O ports2 open module slots; 72 auto-sensing 10/100 ports(IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX), Media Type: Auto-MDIX, Duplex: half or full; Supports a maximum of 120 auto-sensing 10/100 ports or 48 Gigabit ports or 8 mini-GBICs or 2 10-GbE ports, or a combination
    Electromagnetic immunityEN 55024, CISPR 24; IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6; IEC 61000-4-8; IEC 61000-4-11; EN 61000-3-2, IEC 61000-3-2; EN 61000-3-3, IEC 61000-3-3
    Electromagnetic emissionsFCC Class A; VCCI Class A; EN55022/CISPR-22 Class A; CISPR22 Class A; EN55024; IEC/EN61000-3-2; IEC/EN61000-3-3
    Supported protocolsGeneral protocols HTML and telnet management IEEE 802.1AB Link Layer Discovery Protocol (LLDP); RFC 1757 RMON 4 groups: Stats, History, Alarms and Events; RFC 2819 Four groups of RMON: 1 (statistics), 2 (history), 3 (alarm) and 9 (events); RFC 3164 BSD syslog Protocol; RFC 3176 sFlow; ANSI/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED); SNMPv1/v2c/v3; XRMON Network management MIBs Device management IP multicast IEEE 802.1D MAC Bridges; IEEE 802.1p Priority; IEEE 802.1Q VLANs; IEEE 802.1s Multiple Spanning Trees; IEEE 802.1w Rapid Reconfiguration of Spanning Tree; IEEE 802.3ad Link Aggregation Control Protocol (LACP); IEEE 802.3x Flow Control; RFC 768 UDP; RFC 783 TFTP Protocol (revision 2); RFC 791 IP; RFC 792 ICMP; RFC 793 TCP; RFC 826 ARP; RFC 854 TELNET; RFC 1542 BOOTP Extensions; RFC 2030 Simple Network Time Protocol (SNTP) v4; RFC 3046 DHCP Relay Agent Information Option Security RFC 1213 MIB II; RFC 1493 Bridge MIB; RFC 2613 SMON MIB; RFC 2618 RADIUS Client MIB; RFC 2665 Ethernet-Like-MIB; RFC 2668 802.3 MAU MIB; RFC 2737 Entity MIB (Version 2) QoS/Cos RFC 2474 DiffServ Precedence, including 8 queues/port; RFC 2597 DiffServ Assured Forwarding (AF); RFC 2598 DiffServ Expedited Forwarding (EF) IEEE 802.1X Port Based Network Access Control; RFC 2138 RADIUS Authentication; Secure Sockets Layer (SSL); SSHv2 Secure Shell RFC 3376 IGMPv3